Truss Analysis Calculator
Analyse Pratt, Howe, Warren and King Post trusses in seconds. Get every member force, support reaction, tension/compression classification and a colour-coded truss diagram — all from the method of joints.
Understanding Truss Analysis
Truss analysis is the process of finding the internal axial force in every member of a truss and the reactions at its supports. A truss is a triangulated framework of slender members connected at their ends by pins. Because of that triangulation and because loads are applied only at the joints, every member carries a purely axial force — either tension or compression — with no bending.
This calculator performs a full linear-elastic stiffness analysis and reports the results in the language of the classic method of joints.
Equilibrium at every joint:
ΣFx = 0 and ΣFy = 0
Member force from axial deformation:
N = (EA / L) · [(uj − ui)·cos θ + (vj − vi)·sin θ]
Static determinacy check:
m + r = 2j
How the Truss Analysis Calculator Works
Pick a truss type, enter the span and height, choose a load model, and press Analyse Truss. The calculator then:
- Generates the joint coordinates and member connectivity for your truss type and panel count.
- Builds the global stiffness matrix using EA/L terms for each member (EA cancels out for determinate trusses).
- Applies the pin support at the left end and the roller support at the right end.
- Solves the reduced system of equilibrium equations for joint displacements.
- Recovers every member force and every support reaction, then classifies tension vs compression.
- Draws a colour-coded diagram and builds the member force table and chart.
Truss Types Supported
- Pratt truss — parallel chords with verticals, diagonals sloping down toward the centre. Diagonals are in tension, which suits steel. Ideal for medium to long spans.
- Howe truss — the mirror of a Pratt: diagonals slope up toward the centre and are in compression. Historically popular in timber because wood is strong in compression.
- Warren truss — alternating diagonals forming equilateral triangles with no verticals. Fewer members, even force distribution, economical for short to medium spans.
- King Post truss — a simple triangular truss with a single central vertical post. Common in small roof spans and historic buildings.
Tension vs Compression
A member in tension is being stretched — the joints at each end pull it apart. A member in compression is being squeezed — the joints push it together. In a simply supported truss carrying gravity loads, the bottom chord is normally in tension and the top chord is normally in compression. Web members can be either, depending on truss type and position.
This distinction matters for design: tension members can fail by yielding or fracture, while compression members can buckle, so they generally need stockier sections or a smaller effective length.
Zero-Force Members
In an ideal pin-jointed truss, some members carry no force at all. Two classic rules identify them:
- If only two non-collinear members meet at a joint and no external load acts there, both members are zero-force.
- If three members meet at a joint and two are collinear, the third is zero-force when no external load acts there.
Zero-force members are often kept because they stabilise the truss against unsymmetrical loading, support the self-weight of the chords, or reduce the buckling length of adjacent compression members.
Assumptions and Limitations
- Joints are frictionless pins — no moment is transferred between members.
- Members are straight, prismatic and remain elastic.
- Loads are applied only at the joints — no member loading.
- Self-weight, wind, snow and seismic effects are not included unless you enter them as loads.
- Deflections are small, so first-order (linear) equilibrium is valid.
- Results are for a 2D, statically determinate truss; out-of-plane effects and connection eccentricity are ignored.
Use these results as a learning aid or for preliminary sizing. Always have final structural designs checked by a qualified engineer against the governing design code.
❓ Truss Analysis Calculator FAQ
What is truss analysis?
Truss analysis is the process of determining the internal axial forces in each member and the support reactions of a truss. Because truss members are assumed to be pin-jointed and loaded only at the joints, every member carries only axial force — either tension or compression.
What is the difference between tension and compression members?
A tension member is pulled apart by the forces at its ends and elongates. A compression member is pushed together and shortens. In this calculator, positive forces are tension and negative forces are compression.
Which truss type is strongest?
There is no single strongest truss. Pratt trusses place the diagonals in tension and are efficient in steel. Howe trusses place the diagonals in compression and suit timber. Warren trusses use fewer members and give an even force distribution. The right choice depends on span, load, material and cost.
Why do some members have zero force?
In an ideal pin-jointed truss loaded only at the joints, certain members can carry no force. A common case is a joint where two non-collinear members meet with no external load — both forces must then be zero. The King Post vertical is a typical zero-force member under a symmetrical apex load.
What assumptions does this truss calculator make?
The calculator assumes ideal truss behaviour: pin joints, straight members, loads applied only at joints, negligible self-weight and no bending in members. It is a linear elastic, small-deflection analysis.
Is the truss statically determinate?
All trusses generated here are statically determinate: the number of members plus reactions equals twice the number of joints (m + r = 2j). Member forces therefore depend only on geometry and loading, not on member stiffness.
How are the support reactions calculated?
The left support is modelled as a pin (horizontal and vertical reaction) and the right support as a roller (vertical reaction only). Reactions satisfy ΣFx = 0, ΣFy = 0 and ΣM = 0.
How is a uniform load applied to the truss?
A uniform load w over span L gives a total load W = w × L. It is distributed to the top chord joints using tributary lengths: interior joints receive wL/n and end joints receive wL/(2n), where n is the number of panels.
What panel count should I use?
A practical rule is roughly one panel for every 1.5 to 3 metres of span. More panels give a shallower, more efficient truss but more members, joints and fabrication cost. Even panel counts give a symmetrical truss with a centre vertical.
What span-to-height ratio is typical for a truss?
Most trusses use a span-to-height ratio between 5 and 10. A deeper truss reduces chord forces but increases member lengths and web forces. Ratios below 4 waste material; ratios above 12 make the chords very heavily loaded.
Does the result depend on the material?
For a statically determinate truss, no. Member forces come purely from statics and are independent of Young's modulus and cross-sectional area. Material and section properties only affect deflections and stress checks.
Can I use this calculator for a roof or bridge truss?
Yes, as a preliminary sizing and learning tool. For real design, verify results with a qualified structural engineer and include self-weight, wind, snow, seismic loads, connection eccentricity, buckling and code-required load factors.